Fault Diagnosis and Solution MD320/MD320N User Manual
Phase loss failure at the output side
Err 13
Check if the cable connecting the
inverter to the motor is normal
Perform troubleshooting
No
Check if the module is normal
Replace the module
Yes
Check if the three- phase output of therunning
inverter without motor is balanced
Check if the drive board is normal
Replace the drive board
Check if the three-phase
winding of the motor is
normal
Yes
No
Yes
No
Ask for technical support
Fig.8-12 Phase failure at output side(ERR13)
Module over heat
If the ambient temperature is too high
Reduce the ambient
temperature
If the air duct is blocked
Clean the air duct
If the fan is broken
Replace the fan
If the thermal resistor of the module is broken
Replace the thermal resistor
If the inverter module is broken
Replace the inverter module
Ask for technical support
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Fig.8-13 Module overheating (ERR14)
efesotomasyon.com
Summary of Contents for MD320 Series
Page 9: ...z G Gw efesotomasyon com...
Page 16: ...Safety and Precautions MD320 MD320N User Manual efesotomasyon com...
Page 17: ...w Gp efesotomasyon com...
Page 40: ...Product Information MD320 MD320N User Manual efesotomasyon com...
Page 41: ...t G Gl Gp efesotomasyon com...
Page 59: ...v G Gk efesotomasyon com...
Page 67: ...m Gw G efesotomasyon com...
Page 93: ...w Gk efesotomasyon com...
Page 154: ...Parameter Description MD320 MD320N User Manual efesotomasyon com...
Page 155: ...ltjGn efesotomasyon com...
Page 159: ...m Gk G Gz efesotomasyon com...
Page 175: ...h efesotomasyon com...