- 63 -
Parameter Table
Parameter
Parameter Name
Setting Range
Unit
Default
Commission
F8-64
Deceleration time in UPS
mode
0.0 to 20.0
s
3.0
-
F8-65
Brake apply keep
frequency set time
0.00 to 10.00
s
0.50
-
F8-66
Time proportion of
S-curve at Stop stage
start
0.0% to Min. [(100.0% - F8-67),
80%]
%
20.0
-
F8-67
Time proportion of
S-curve at Stop stage
end
0.0% to Min. [(100.0% - F8-66),
80%]
%
30.0
-
F8-68
UPS input phase mode
selection
0: Three phase UPS
1: Single-/Two-phase UPS
N.A
0
-
F8-69
Single-/Two-phase UPS
under voltage point
60.0 to 140.0
%
60.0
60% is 210V
F8-70
ON delay time for rescue
operation
0.0 to 20.0
s
0.0
-
F8-71
Regeneration load slip
50% to 200%
%
100
-
F8-72
Rescue operation
0: Disable
1: Enable
N.A
0
-
F8-73
Rescue direction check
time
0.0 to 10.0
s
1.0
-
F8-75
Rescue mode under
voltage error display
0: Disable
1: Enable
N.A
0
-
F8-76
Reference speed
terminal
0: Direction
1: Speed
N.A
0
-
F8-77
Change control mode
0: Disable
1: Enable
N.A
0
-
F8-78
V/F mode multi-point
percentage
0% to 100%
%
100
-
F8-79
OFF delay time for
rescue operation
0.0 to 240.0
s
0.0
-
F8-80
Short-floor function
0: Disable
1: Enable
N.A
0
-
F8-81
High frequency limit
F8-82 to F0-10
Hz
40.00
-
F8-82
Low frequency limit
0.00 to F8-81
Hz
30.00
-
F8-83
Short-floor running time
0.0 to 10.0
s
4.0
-
F8-84
Short-floor frequency
delay time
0.0 to 4.0
s
0.0
-