- 62 -
Parameter Table
Group F7: product and software version checking
Parameter
Parameter Name
Setting Range
Unit
Default Commission
F7-08
Product number
N.A
N.A
380.00
display
F7-10
Performance software
version
N.A
N.A
-
display
F7-11
Functional software
version
N.A
N.A
-
display
F7-15
Performance software
temporary version
N.A
N.A
-
display
F7-16
Functional software
temporary version
N.A
N.A
-
display
Group F8: auxiliary functions
Parameter
Parameter Name
Setting Range
Unit
Default
Commission
F8-04
Stop stage deceleration
time
0.0 to 6500.0
s
2.0
-
F8-26
Frequency switchover
point between
deceleration time 1 and
deceleration time 2
0.00 to max. frequency
Hz
0.00
-
F8-55
Brake release current
threshold
0 to 200
%
20
-
F8-56
Brake release frequency
threshold
0.00 to 25.00
Hz
0.20
-
F8-57
Brake release delay ON
set time
0.0 to 5.0
s
0.2
-
F8-58
Brake apply frequency
threshold
0.00 to 25.00
Hz
0.20
-
F8-59
Brake apply delay OFF
set time
0.0 to 5.0
s
0.2
-
F8-60
Drive run delay ON set
time
0.20 to 10.00
s
0.20
-
F8-61
MC contactor delay OFF
set time
0.00 to 10.00
s
0.20
-
F8-62
Current threshold in UPS
mode
0.0 to 200.0
%
100.0
-
F8-63
Acceleration time in UPS
mode
0.0 to 20.0
s
3.0
-