POTENTIAL PROBLEMS - CAUSES - SOLUTIONS
PROBLEM CAUSE SOLUTION
1
-Dishes are not clean.
-Washing arms may be stuck.
-Washing water sprays may be
blocked.
-Rinsing water sprays may be
blocked.
-Detergent concentration may be
very high or insufficient.
-Filter may be blocked.
-Washing time may be insufficient.
-Check whether the dishes prevent arms from rotating.
-Clean the water sprays by removing the washing arm.
-Clean the water sprays by removing the rinsing arm.
-Check the hardness of water.
-Check the detergent amount.
-Remove and clean the filter.
-Select a longer wash period or repeat the same period.
2
-Dishes are getting broken.
-Proper tray may not have been
used.
-Machine
may
have
been
overloaded.
-Be careful when selecting the tray.
-Comply with its capacity.
3
-The device does not take
water.
-Water inlet valve may be closed.
-Cover
may
not
be
closed
completely.
-Solenoid valve may be broken.
-Check/Open
-Check/Close
-Notify the authorized service.
4
-The device continuously
takes water.
-Pressure stat may be defective.
-Pressure stat hose may have taken
in air.
-Notify the authorized service.
-Empty the water inside the tank and restart the device.
5
-There is rusting on the
device surface
-Improper chemical materials
may have been used.
-Clean the device according to the instructions for use
BYM102 Malfunction Codes:
In case of malfunction, your device turns itself OFF and the related malfunction codes are displayed on the
screen
(as can be seen above)
.
Malfunction codes are removed by themselves when the Sensor and Thermal malfunctions are solved.
To remove other codes, push the ON/OFF button.
DESCRIPTION
DETECTION
ER 01
NO WATER
Malfunction
Tank pressurestat does not detect the water level for 10 min. if its
position is not changed.
(if no signal is received for 10 min. at input no.9 during machine
water intake)
ER 02
Boiler NTC Malfunction
Sensor short or open circuited
ER 03
Tank NTC Malfunction
Sensor short or open circuited
ER 04
Boiler HEATER
Malfunction
When temperature increase of at least 5 ºC(41°F) is not ensured for
10 min. in the boiler.
(To be controlled when the boiler output no.11, i.e. the K2
contactor, has been working for at least 10 min. continuously.)
ER 05
Tank HEATER
Malfunction
When temperature increase of at least 5 ºC(41°F) is not ensured for
15 min. in the tank.
(To be controlled when the boiler output no.10, i.e. the K3
contactor, has been working for at least 15 min. continuously.)
ER 06
Thermal Relay or
Power-box Malfunction
When there is no energy at washer pump thermal relay output
(When there is no energy at input no.16 of the electronic card)
Summary of Contents for BYM102
Page 2: ...2 ekil 1...
Page 34: ...34 START START M1 5 Y1 M2 PD ON 2 OFF START PAUSE 2 STOP...
Page 35: ...35 85 C ECOMOD 0 999 85 C ECOMOD 0 5 5 START 2 6 2 3 1 60 2 120 3 180 500x500 1 1 1...
Page 36: ...36 7 ON OF 2 0 10 10 11 2 3 1...
Page 37: ...37 1 2 3 4 5 BYM102 OFF ER 01 10 9 ER 02 NTC ER 03 NTC ER 04 5 C 41 F 10 11 2 10...
Page 38: ...38 ER 05 5 41 F 15 10 3 15 ER 06 16 ON OFF...
Page 39: ...39 BYM 102 ELEKTR K EMASI...
Page 40: ...40 BYM 102 ELECTRIC SCHEMA...
Page 41: ...41 BYM 102 ESQUEMA EL CTRICO...
Page 42: ...42 BYM 102 SCH MA LECTRIQUE...
Page 43: ...43 BYM 102 SCHEMA ELETTRICO BYM 102...
Page 44: ...44...