3.4.26 “e1” High Pressure Sensor Error
Error display:
ODU mainboard LED displayer
Sample the AD value of pressure sensor through pressure sensor detecting circuit and judge the range of
AD value, If the sampling AD value exceeds upper limit and lower limit in 30 seconds continuously, report the
error.
Poor contact between pressure sensor and terminal in mainboard interface
Pressure sensor is abnormal
Detecting circuit is abnormal
Troubleshooting
:
3.4.27 “C4” ODU Jumper Cap Error
Error display:
ODU mainboard LED displayer
Error judgment condition and method:
If jumper cap model doesn‘t match with mainboard, report the error