Drive board IPM module’s 15V power supply is lower than 13.5V.
Drive board 6-line PWM signal and the corresponding element are abnormal.
Drive board compressor current sampling circuit element is damaged or drive chip current sampling AD terminal
is abnormal.
Compressor is damaged.
Troubleshooting
:
3.4.11 “H6” DC Fan Error
Error display:
ODU mainboard LED displayer
Error judgment condition and method:
Mainboard doesn’t receive the signal of outdoor fan within 30s after the outdoor fan starts up.