10
[1] Pow e r k e y
Pr ess and hold t he Power Key for > 3 seconds t o pow er on/ off t he cam era.
! N ot e
: Aft er pow er ing off, please wait t en seconds befor e pow er ing t he
cam era on again.
[2] Se le ct / Au t o k e y ( M a r k ed “A”)
The “A” or at t r ibut e but t on per form s 2 funct ions.
a) The first funct ion is m odificat ion of select ed param et ers. I t is obt ained
by a quick pr ess and r elease ( less t han 2 seconds) , w it h t his funct ions t o
m odify t heir param et er s. Subsequent presses will “ scr oll” t hrough t he
available param et er s. The select ed funct ion w ill be highlight ed in yellow. The
funct ions include:
•
M e a sur e m e n t poin t s, a r e a s, a n d lin e s
Point s, ar eas, lines – sw it ching t he added point s, ar eas and lines in t he
int er face fr om Up t o Dow n, pr ess Menu t o set pr opert ies, pr ess C t o delet e t he
select ed m easur ing obj ect s.
Color Pa le t t e
Pr essing t he left or r ight arr ow s w ill scr oll t hr ough t he available color
palet t es, displaying t heir nam e above t he palet t e. The select ed palet t e will
becom e act ive aft er about 3 seconds of select ing it and will be set as t he
default pow er on palet t e.
•
Le v e l/ Spa n v a lu e s
Pr essing t he left or r ight arr ow w ill r educe or incr ease t he Span and
pr essing t he up or down arr ow w ill r educe or incr ease t he Level. I f t he unit is
in Aut om at ic m ode, m odifying any of t hese param et er s w ill select Manual
m ode.
b
)
The second funct ion per form ed is t o force an int ernal calibrat ion cycle.
This is perform ed by pr essing and holding t he
A
key for 5
seconds or m or e.
The cam era w ill m ake aut om at ic cor r ect ion t o get t he m ost accurat e t herm al
m easur em ent .
c) I m age t ransm ission via blue t oot h. Open blue- t oot h, select obj ect im age,