User Manual V1.3 | XtracontrolDC2, XtracontrolET2, XtracontrolEC21
6.2.3
XtracontrolEC21
The device must be connected to the network with the correct settings before it can be used.
Fig. 41: identification plate with device serial number 00001 (example)
1.
Note down the IP address and subnet mask:
IP address: 169.254.255.XX
XX corresponds to the last 2 digits of the device serial number. Exception: 00 becomes 100.
Subnet mask: 255.255.255.0
NOTICE
Damage to property
▶
Before connecting the power supply, ensure that all cabling is
correct, including the polarity of all the connections.
2.
Supply the device with power (24 V).
3.
Connect the device to a programming computer using a network cable (X4) and network switch.
4.
Open a web browser on the programming computer.
5.
Enter the IP address of the device into the web browser.
The login screen will appear.
Fig. 42: login window
6.
Use the following user name and password to log into the device:
Name: admin
Password: admin
56
©