User Manual V1.3 | XtracontrolDC2, XtracontrolET2, XtracontrolEC21
Fig. 9: Installation cut-out, XtracontrolDC2.07 and XtracontrolET2.07
▶
Cut a rectangular installation cut-out in the support material:
Height: 136.5 mm
Width: 187.0 mm
Max. corner radius: 3.0 mm
Thickness of the support material:
Protection class IP65 with twist-lock catches: only at 1.5–3.0 mm
Optimal: 1.5–2.0 mm
Max.: 3.0 mm
© Infranor GmbH
23