Measuring Current Consumption in Different Power Modes
www.cypress.com
Document No. 002-14914 Rev. *C
5
d.
Select the
CTS flow control
check box, and then click
OK
.
Reset the DUT/reference board
1.
While in HCI Control, press the
3 key
on the keyboard to select the Host controller & baseband commands.
2.
In the list of Host controller & baseband commands, double-click
Reset
. In Log Window, verify that the DUT/
reference board has been reset.
Download the minidriver
1.
In HCI Control, press the
0 key
on the keyboard to select the Vendor-specific commands.
2.
In the list of commands, double-click
Download Minidriver
. When the command has completed executing,
verify that the
HCI protocol active
check box has been cleared, that HCI Control is no longer active, and that
Transport Closed
is displayed in Log Window.
Download the configuration file
1.
On the
Transport
menu, click
Download Firmware/Config
.
2.
In Select Download Firmware/Config Transport, select the COM port used by the DUT (
com4
)/reference board
(
com5
), and then click
OK
.
3.
In Download: com4@115200/com5@115200:
a.
In the
Device configuration
list, select the device you want to configure.
b.
Select the
Download configuration
record
check box.