
Measuring Current Consumption in Different Power Modes
www.cypress.com
Document No. 002-14914 Rev. *C
23
■
In the top
UART
list, type the COM port of the PC that the DUT is connected to (
com4
).
■
In the bottom
UART
list, select
115200
.
■
Select the
CTS flow control
check box, and then click
OK
.
Reset the DUT
1.
While in HCI Control, press the
3 key
on the keyboard to select the Host Controller & Baseband commands.
2.
In the list of Host Controller & Baseband commands, double-click
Reset
.
Set the HCI Control Transport profile on the reference board
1.
On the
Transport
menu, click
HCI Control
.
2.
In HCI Control Window Transport:
a.
Select
UART
.
b.
In the top
UART
list, type the COM port of the PC that the DUT is connected to (
com5
).
c.
In the bottom
UART
list, select
115200
.
d.
Select the
CTS flow control
check box, and then click
OK
.
Reset the reference board
1.
While in HCI Control, press the
3 key
on the keyboard to select the Host Controller & Baseband commands.
2.
In the list of Host Controller & Baseband commands, double-click
Reset
.
Read and record the BD Address of the DUT
1.
Reestablish the HCI Control Transport profile for the DUT (
com4
).
2.
While in HCI Control: com4@115200, press the
4 key
on the keyboard to select the Informational Parameters
commands.
3.
In the list of Informational Parameters commands, double-click
Read_BD_ADDR
.
4.
Verify that the BD Address is displayed in Log Window and note the address for later use.
Set the Event Filter parameters on the DUT
1.
While in HCI Control: com4@115200, press the
3 key
on the keyboard to select the Host Controller &
Baseband commands.
2.
In the list of Host Controller & Baseband commands, double-click
Set_Event_Filter
.
3.
In HCI Command: Set_Event_Filter (com4@115200):
a.
In the
Filter_Type
list, select
Connection Setup
.
b.
In the
Connection_Setup_Filter_Condition_Type
list, select
Allow Connections from all devices
.
c.
In the
Auto_Accept_Flag
list, select
Do Auto accept the connection with role switch disabled
, and
then click
OK
.
Set the Write Scan Enable parameters on the DUT
1.
In the list of Host Controller & Baseband commands, double-click
Write_Scan_Enable
.
2.
In HCI Command: Write_Scan_Enable (com4@115200), in the
Scan_Enable
list, select
Inquiry and Page
Scan enabled
, and then click
OK
.
Read and record the BD Address of the reference board
1.
Reestablish the HCI Control Transport profile for the reference board (
com5
).
2.
While in HCI Control: com5@115200, press the
4 key
on the keyboard to select the Informational Parameters
commands.
3.
In the list of Informational Parameters commands, double-click
Read_BD_ADDR
.
4.
Verify that the BD Address is displayed in Log Window and note the address for later use.