Measuring Current Consumption in Different Power Modes
www.cypress.com
Document No. 002-14914 Rev. *C
3
3
Overview and Orientation
3.1
Overview
This document provides procedures for measuring the amount of current consumed by BCM4324/BCM4334
devices while in different modes. The modes for which such procedures are provided include the following:
■
Sleep mode
■
Standard 1.28s Inquiry Scan mode
■
Standard 2.56s Inquiry Scan mode
■
Standard Page Scan mode
■
SNIFF_500ms_Master mode
■
SNIFF_500ms_Slave mode
■
HV(3/2) for DUT as Master mode
■
HV(3/2) for DUT as Slave mode
■
EV(4/5) eSCO for DUT as Master mode
■
EV(4/5) eSCO for DUT as Slave mode
■
Throughput ACL, 3DH5 mode
Note:
For information regarding the measurement of current consumption of Bluetooth Low Energy devices, refer
to the document cited in
3.2
Orientation
The following provides information that the user needs to know before starting to make current consumption mea-
surements:
■
Cypress BlueTool™ is used to place the device under test (DUT) in each mode. To obtain the latest version,
contact your Cypress representative.
■
The equipment needed for making power consumption measurements is described in
■
It is assumed that you are familiar with BlueTool and that you know how to set up and use the equipment
needed for measuring current consumption.
■
The procedure for downloading the BlueTool configuration and minidriver files to the DUT and reference board
is also provided (see
Downloading the Minidriver and Configuration File on page 4
). You must download these
files to the devices before you begin setting the various modes.
■
In this document,
HCI control: com4
refers to the DUT, and
HCI Control: com5
refers to the reference board.
The actual COM port number may be different for each test system.
■
The number key shortcuts to switch to the various HCI command lists refer to the number keys above the letter
keys on the keyboard.
■
WLAN core is in reset (WL_REG_ON = low) for all measurements.
4
Test Setup
4.1
System Requirements
The system requirements are as follows:
■
Host system
A PC running Microsoft® Windows® (either Windows XP or Windows 7) is required to use BlueTool.
■
Test equipment
❐
Agilent variable attenuator (Agilent 8496A Attenuator/110 dB)
❐
Ammeter (Agilent 34410A digital Multimeter or Agilent 6705B DC Power Analyzer)
❐
DUT (BCM4324/BCM4334)
❐
Reference board (Reference boards are available from Cypress.)
❐
USB/RS-232 serial DB9 (straight-through) cables
❐
USB to UART converter
■
Software