Measuring Current Consumption in Different Power Modes
www.cypress.com
Document No. 002-14914 Rev. *C
27
Read and record the BD Address of the reference board
1.
Reestablish the HCI Control Transport profile for the reference board (
com5
).
2.
While in HCI Control: com5@115200, press the
4 key
on the keyboard to select the Informational Parameters
commands.
3.
In the list of Informational Parameters commands, double-click
Read_BD_ADDR
.
4.
Verify that the BD Address is displayed in Log Window and note the address for later use.
Set the Event Filter parameters on the reference board
1.
While in HCI Control: com5@115200, press the
3 key
on the keyboard to select the Host Controller &
Baseband commands.
2.
In the list of Host Controller & Baseband commands, double-click
Set_Event_Filter
.
3.
In HCI Command: Set_Event_Filter (com5@115200):
a.
In the
Filter_Type
list, select
Connection Setup
.
b.
In the
Connection_Setup_Filter_Condition_Type
list, select
Allow Connections from all devices
.
c.
In the
Auto_Accept_Flag
list, select
Do Auto accept the connection with role switch disabled
, and
then click
OK
.
Set the Write Scan Enable parameters on the reference board
1.
In the list of Host Controller & Baseband commands, double-click
Write_Scan_Enable
.
2.
In HCI Command: Write_Scan_Enable (com5@115200), in the
Scan_Enable
list, select
Inquiry and Page
Scan enabled
, and then click
OK
.
Read the local supported features on the reference board
1.
While in HCI Control: com5@115200, press the
4 key
on the keyboard to select the Informational Parameters
commands.
2.
In the list of Informational Parameters commands, double-click
Read_Local_Version_Information
and note
which SCO Links are supported for the device being tested.
Write the local supported features on the reference board
1.
While in HCI Control: com5@115200, press the
0 key
on the keyboard to select the Vendor-specific
commands.
2.
In the list of Vendor-specific commands, double-click
Write_Local_Supported_Features
.
3.
In HCI Command: Write_Local_Supported_Features (com5@115200), clear the
Power control
check box.
Read the local supported features on the DUT
1.
Reestablish the HCI Control Transport profile for the DUT (
com4
).
2.
While in HCI Control: com4@115200, press the
4 key
on the keyboard to select the Informational Parameters
commands.
3.
In the list of Informational Parameters commands, double-click
Read_Local_Version_Information
and note
which SCO Links are supported for the device being tested.
Write the local supported features on the DUT
1.
While in HCI Control: com4@115200, press the
0 key
on the keyboard to select the Vendor-specific
commands.
2.
In the list of Vendor-specific commands, double-click
Write_Local_Supported_Features
.
3.
In HCI Command: Write_Local_Supported_Features (com4@115200), clear the
Power control
check box.
From the DUT, create a connection to the reference board
1.
While in HCI Control: com4@115200, press the
1 key
on the keyboard to select the Link Control commands.
2.
In the list of Link Control commands, double-click
Inquiry
to display a list of found devices.