Infineon Cypress BCM4334 Manual Download Page 25

Measuring Current Consumption in Different Power Modes

www.cypress.com

Document No. 002-14914 Rev. *C

24

Set the Event Filter parameters on the reference board

1.

While in HCI Control: com5@115200, press the 

3 key

 on the keyboard to select the Host Controller & 

Baseband commands.

2.

In the list of Host Controller & Baseband commands, double-click 

Set_Event_Filter

.

3.

In HCI Command: Set_Event_Filter (com5@115200):

a.

In the 

Filter_Type

 list, select 

Connection Setup

b.

In the 

Connection_Setup_Filter_Condition_Type

 list, select 

Allow Connections from all devices

.

c.

In the 

Auto_Accept_Flag

 list, select 

Do Auto accept the connection with role switch disabled

, and 

then click 

OK

Set the Write Scan Enable parameters on the reference board

1.

In the list of Host controller & baseband commands, double-click 

Write_Scan_Enable

.

2.

In HCI Command: Write_Scan_Enable (com5@115200), in the 

Scan_Enable

 list, select 

Inquiry and Page 

Scan enabled

, and then click 

OK

.

Read the local supported features on the reference board

1.

While in HCI Control: com5@115200, press the 

4 key

 on the keyboard to select the Informational Parameters 

commands.

2.

In the list of Informational parameters commands, double-click 

Read_Local_Version_Information

 and note 

which SCO Links are supported for the device being tested.

Write the local supported features on the reference board

1.

While in HCI Control: com5@115200, press the 

0 key

 on the keyboard to select the Vendor-specific 

commands.

2.

In the list of Vendor-specific commands, double-click 

Write_Local_Supported_Features

.

3.

In HCI Command: Write_Local_Supported_Features (com5@115200), clear the 

Power control 

check box.

Read the local supported features on the DUT

1.

Reestablish the HCI Control Transport profile for the DUT (

com4

).

2.

While in HCI Control: com4@115200, press the 

4 key

 on the keyboard to select the Informational Parameters 

commands.

3.

In the list of Informational Parameters commands, double-click 

Read_Local_Version_Information

 and note 

which SCO Links are supported for the device being tested.

Write the local supported features on the DUT

1.

While in HCI Control: com4@115200, press the 

0 key

 on the keyboard to select the Vendor-specific 

commands.

2.

In the list of Vendor-specific commands, double-click 

Write_Local_Supported_Features

.

3.

In HCI Command: Write_Local_Supported_Features (com4@115200), clear the 

Power control 

check box.

Create a connection from the reference board

1.

Reestablish the HCI Control Transport profile for the reference board (

com5

).

2.

While in HCI Control: com5@115200, press the 

1 key

 on the keyboard to select the Link Control commands.

3.

In the list of Link Control commands, double-click 

Inquiry

 to display a list of found devices.

4.

In the list of Link Control commands, double-click 

Create_Connection

.

5.

In HCI Command: Create_Connection (com5@115200):

a.

In the 

BD_ADDR

 list, select the BD address (of the DUT) that was noted earlier.

b.

Set the packet type by selecting the following check boxes:

DM1

DM3

Summary of Contents for Cypress BCM4334

Page 1: ...rs as part of the Infineon product portfolio Continuity of document content The fact that Infineon offers the following product as part of the Infineon product portfolio does not lead to any changes t...

Page 2: ...Design Support 37 1 About This Document 1 1 Purpose and Audience This document is intended for use by Cypress and customers test engineers 1 2 Cypress Part Numbering Scheme Cypress is converting the...

Page 3: ...he right IoT device for your design and quickly and effectively integrate the device into your design Cypress provides cus tomer access to a wide range of information including technical documentation...

Page 4: ...measurements is described in System Requirements on page 3 It is assumed that you are familiar with BlueTool and that you know how to set up and use the equipment needed for measuring current consumpt...

Page 5: ...est mode The ammeter range setting is specified in the procedure for that test mode 4 3 Downloading the Minidriver and Configuration File This section provides instructions for downloading the minidri...

Page 6: ...the keyboard to select the Vendor specific commands 2 In the list of commands double click Download Minidriver When the command has completed executing verify that the HCI protocol active check box h...

Page 7: ...for the purpose of measur ing the amount of current being consumed by the device when it is in each mode This section also specifies the ammeter range for making current readings in each mode 5 1 Slee...

Page 8: ...Host controller baseband commands 2 In the list of Host Controller Baseband commands double click Reset In Log Window verify that the DUT has been reset Set the Sleepmode parameters 1 In HCI Control c...

Page 9: ...the Scan Type Generate 2048 slots of 1 28s activity Set the Current IAC Lower Address Portion LAP parameters Set the Write Scan Enable parameters This section concludes by specifying the approximate...

Page 10: ...d commands 2 In the list of Host Controller Baseband commands double click Write_Inquiry_Scan_Type 3 In HCI Command Write_Inquiry_Scan_Type com4 115200 in the Scan_Type list select Mandatory Standard...

Page 11: ...DUT is connected to com4 In the bottom UART list select 115200 Select the CTS flow control check box and then click OK Reset the DUT 1 In HCI Control com4 115200 press the 3 key on the keyboard to se...

Page 12: ...proximate range of the ammeter to 0 2 mA and measure the current being consumed by the DUT 5 4 Standard Page Scan This section explains how to set the BCM4324 BCM4334 to Standard Page Scan mode Steps...

Page 13: ...and commands double click Write_Page_Scan_Activity 2 In HCI Command Write_Page_Scan_Activity com4 115200 a For the Page_Scan_Interval type 2048 in the space provided b For the Page_Scan_Window type 0x...

Page 14: ...mmands double click Reset Set the Sleepmode parameters on the DUT 1 While in HCI Control com4 115200 press the 0 key on the keyboard to select the Vendor specific commands 2 In the list of Vendor spec...

Page 15: ..._Setup_Filter_Condition_Type list select Allow Connections from all devices c In the Auto_Accept_Flag list select Do Auto accept the connection with role switch disabled and then click OK Set the Writ...

Page 16: ...keyboard to select the Link Policy commands 3 In the list of Link Policy commands double click Write_Link_Policy_Settings 4 In HCI Command Write_Link_Policy_Settings com4 115200 select the Enable Snif...

Page 17: ...rence board Set the Sniff Mode parameters on the reference board This section concludes by specifying the approximate ammeter range setting for measuring the current being con sumed by the DUT Before...

Page 18: ...e_Scan_Enable com4 115200 in the Scan_Enable list select Inquiry and Page Scan enabled and then click OK Set the Event Filter parameters on the DUT 1 In the list of Host Controller Baseband commands d...

Page 19: ...select the Enable Sniff Mode check box and then click OK Set the Sniff_Mode parameters for the DUT 1 Reestablish the HCI Control Transport profile for the DUT com4 2 While in HCI Control com4 115200 p...

Page 20: ...ds double click Reset Set the HCI Control Transport profile on the reference board 1 On the Transport menu click HCI Control 2 In HCI Control Window Transport a Select UART b In the top UART list type...

Page 21: ...elect Allow Connections from all devices c In the Auto_Accept_Flag list select Do Auto accept the connection with role switch disabled and then click OK Set the Write Scan Enable parameters on the ref...

Page 22: ...then click OK Note that the connection handle 0xB This is an ACL connection Set the Write Scan Enable parameters on the reference board 1 Reestablish the HCI Control Transport profile for the referen...

Page 23: ...ad and record the BD Address of the reference board Set the Event Filter parameters on the reference board Set the Write Scan Enable parameters on the reference board Read the local supported features...

Page 24: ...Parameters commands 3 In the list of Informational Parameters commands double click Read_BD_ADDR 4 Verify that the BD Address is displayed in Log Window and note the address for later use Set the Eve...

Page 25: ...ress the 0 key on the keyboard to select the Vendor specific commands 2 In the list of Vendor specific commands double click Write_Local_Supported_Features 3 In HCI Command Write_Local_Supported_Featu...

Page 26: ...t and the indication that the connection was complete Measure the current consumption Set the approximate range of the ammeter to 10 mA and measure the current being consumed by the DUT 5 9 EV 4 5 eSC...

Page 27: ...rd to select the Host Controller Baseband commands 2 In the list of Host Controller Baseband commands double click Reset Read and record the BD Address of the DUT 1 Reestablish the HCI Control Transpo...

Page 28: ...1 While in HCI Control com5 115200 press the 4 key on the keyboard to select the Informational Parameters commands 2 In the list of Informational Parameters commands double click Read_Local_Version_I...

Page 29: ...trol commands double click Setup_Synchronous_Connection 4 In HCI Command Add_SCO_Connection com4 115200 a In the Connection_Handle list select the connection handle indicated in Log Window b Select on...

Page 30: ...click HCI Control 2 In HCI Control Window Transport a Select UART b In the top UART list type the COM port of the PC that the reference board is connected to com5 c In the bottom UART list select 1152...

Page 31: ...ble parameters on the reference board 1 In the list of Host Controller Baseband commands double click Write_Scan_Enable 2 In HCI Command Write_Scan_Enable com5 115200 in the Scan_Enable list select In...

Page 32: ...nection from the DUT 1 While in HCI Control com5 115200 press the 1 key on the keyboard to select the Link Control commands 2 In the list of Link Control commands double click Setup_Synchronous_Connec...

Page 33: ...15200 press the 3 key on the keyboard to select the list of Host Controller Baseband commands In the list double click Set_Event_Filter In HCI Command Set_Event_Filter com 115200 a In the Filter_Type...

Page 34: ...ndow for the DUT press the 4 key to select the list of Informational Parameters In the list double click Read_BD_ADDR In Log Window verify that BD_ADDR 111111111111 is displayed 3 While in the HCI Con...

Page 35: ...Receive test on the reference device and the Transmit test on the DUT 1 On the Transport menu click Throughput Test 2 In Throughput Tests com 3000000 com is the COM number of the reference device a Un...

Page 36: ...the DUT click Execute Test Note that the data flow values throughput are approximately 2000 KBit sec for both the Transmit and Receive tests Measure the current consumption Set the approximate range o...

Page 37: ...wer Modes Document Number 002 14914 Rev ECN No Orig of Change Submission Date Description of Change 07 03 2012 4324_4334 AN101 R Initial release A 08 06 2012 4324_4334 AN100 R Updated System Requireme...

Page 38: ...roperly design program and test the functionality and safety of any application made of this information and any resulting product Cypress products are not designed intended or authorized for use as c...

Reviews: