Measuring Current Consumption in Different Power Modes
www.cypress.com
Document No. 002-14914 Rev. *C
17
■
Host_WAKE_Active_Mode
Active Low
b.
Select the following check boxes, and then click
OK
:
■
Allow_Host_Sleep_During_SCO
■
Combine_Sleep_Mode_And LPM
■
Enable_Tristate_Control_Of_UART_Tx_Line
Read and record the BD Address of the DUT
1.
On the
Transport
menu, click
HCI Control
.
2.
In HCI Control Window Transport:
a.
Select
UART
.
b.
In the top
UART
list, type the COM port of the PC to which the DUT is connected (
com4
).
c.
In the bottom
UART
list, select
115200
.
d.
Select the
CTS flow control
check box, and then click
OK
.
3.
While in HCI Control: com4@115200, press the
4 key
on the keyboard to select the Informational Parameters
commands.
4.
In the list of Informational Parameters commands, double-click
Read_BD_ADDR
.
5.
Verify that the BD Address is displayed in Log Window and note the address for later use.
Set the Write Scan Enable parameters on the DUT
1.
While in HCI Control: com4@115200, press the
3 key
on the keyboard to select the Host Controller &
Baseband commands.
2.
In the list of Host Controller & Baseband commands, double-click
Write_Scan_Enable
.
3.
In HCI Command: Write_Scan_Enable (com4@115200), in the
Scan_Enable
list, select
Inquiry and Page
Scan enabled
, and then click
OK
.
Set the Event Filter parameters on the DUT
1.
In the list of Host Controller & Baseband commands, double-click
Set_Event_Filter
.
2.
In HCI Command: Set_Event_Filter (com4@115200):
a.
In the
Filter_Type
list, select
Connection Setup
.
b.
In the
Connection_Setup_Filter_Condition_Type
list, select
Allow Connections from all devices
.
c.
In the
Auto_Accept_Flag
list, select
Do Auto accept the connection with role switch disabled
, and
then click
OK
.
Create a connection from the reference board
1.
Reestablish the HCI Control Transport profile for the reference board (
com5
).
2.
While in HCI Control: com5@115200, press the
1 key
on the keyboard to select the Link Control commands.
3.
In the list of Link Control commands, double-click
Inquiry
to display a list of found devices.
4.
In the list of Link Control commands, double-click
Create_Connection
.
5.
In HCI Command: Create_Connection (com5@115200):
a.
In the
BD_ADDR
list, select the BD address (of the DUT) that was noted earlier.
b.
Set the packet type by selecting the following check boxes:
■
DM1
■
DM3
■
DM5
c.
In the
Page_Scan_Repetition_Mode
list, select
R0
.
d.
In the
Page_Scan_Mode
list, select
Mandatory
, and then click
OK
.
6.
In Log Window, verify that the devices have successfully connected and note the connection handle for later
use.