Measuring Current Consumption in Different Power Modes
www.cypress.com
Document No. 002-14914 Rev. *C
35
c.
In the
Count
box, type a value of at least
16000000
.
5.
Under
Receive Test
in Throughput Tests: com#@3000000 for the reference device, click
Execute Test
.
6.
Under
Transmit Test
in Throughput Tests: com#@3000000 for the DUT, click
Execute Test
.
Note that the data flow values (throughput) are approximately 2000 KBit/sec for both the Transmit and Receive
tests.
Measure the current consumption
Set the approximate range of the ammeter to 10 mA and measure the current being consumed by the DUT.
6
References
The references in this section may be used in conjunction with this document.
Document (or Item) Name
Number
Source
Cypress Items
[1]
Bluetooth Low Energy Current Consumption Measurements
4330-AN4XX-R