26/126
Chart 2 pipe (analog output, heating)
Chart 2 pipe (digital output, heating)
100
0
Temp.
Outputs
BCS
(
I08
)
100
0
Temp.
Outputs
ON
OFF
Temp
Outputs
BCS
(
I08
)
ON
OFF
Temp
Outputs
(
I12
o
I13
)
(
I12
o
I13
)
WCS
WCS
WCS
WCS
ECONOMY
or
HOLIDAY
ECONOMY
or
HOLIDAY
100
0
Temp.
Outputs
BHS
(
I07
)
100
0
Temp.
Outputs
ON
OFF
Temp
Outputs
BHS
(
I07
)
ON
OFF
Temp
Outputs
(
I12
o
I13
)
WHS
WHS
WHS
WHS
ECONOMY
or
HOLIDAY
ECONOMY
or
HOLIDAY
(
I12
o
I13
)
100
0
Temp.
Outputs
BCS
(
I08
)
100
0
Temp.
Outputs
ON
OFF
Temp
Outputs
BCS
(
I08
)
ON
OFF
Temp
Outputs
(
I12
o
I13
)
(
I12
o
I13
)
WCS
WCS
WCS
WCS
ECONOMY
or
HOLIDAY
ECONOMY
or
HOLIDAY
100
0
Temp.
Outputs
BHS
(
I07
)
100
0
Temp.
Outputs
ON
OFF
Temp
Outputs
BHS
(
I07
)
ON
OFF
Temp
Outputs
(
I12
o
I13
)
WHS
WHS
WHS
WHS
ECONOMY
or
HOLIDAY
ECONOMY
or
HOLIDAY
(
I12
o
I13
)
Chart 4 pipe (analog output)
Chart 4 pipe (digital output)
100
0
Temp.
Outputs
BS4P
(
I09
)
100
0
Temp.
Outputs
BS4P
(
I09
)
ON
OFF
Temp
Outputs
BS4P
(
I09
)
ON
OFF
Temp
Outputs
BS4P
(
I09
)
(
I12
o
I13
)
(
I12
o
I13
)
(
I12
o
I13
)
(
I12
o
I13
)
WCS
WHS
WCS
WHS
WCS
WHS
WCS
WHS
ECONOMY
or
HOLIDAY
ECONOMY
or
HOLIDAY
100
0
Temp.
Outputs
BS4P
(
I09
)
100
0
Temp.
Outputs
BS4P
(
I09
)
ON
OFF
Temp
Outputs
BS4P
(
I09
)
ON
OFF
Temp
Outputs
BS4P
(
I09
)
(
I12
o
I13
)
(
I12
o
I13
)
(
I12
o
I13
)
(
I12
o
I13
)
WCS
WHS
WCS
WHS
WCS
WHS
WCS
WHS
ECONOMY
or
HOLIDAY
ECONOMY
or
HOLIDAY
It is possible to visualize the working setpoint by setting parameter
I42
or
I43
to 6. On this case the value of
WHS
is visualized
in heating mode, the value of
WCS
is visualized in cooling mode and if working season is not defined (
I54
=2, and temperature
of water sensor between
I15
and
I16
), the message “---“ is visualized.
If no contacts or sensors are configured in “not occupied holiday” or "energy saving" mode, and if the operating mode has
been set manually with time zones (see
“4. Quick access parameter setting” page 8
), then within the time zone regulation
is controlled with the basic setpoint; in this case “display C” (see
“3. Display, keyboard and icons” page 7
) indicates the
number of the active zone. Outside the time zone, economy mode is active.
Otherwise, the contact or sensor status configured in “not occupied holiday” or “energy saving” mode has higher priority, and
time zones are not considered (
TH-xxCSx1
models)
If no contacts or sensors are configured as “not occupied holiday” or “energy saving” and if operating mode is in holiday mode
(manually set using quick access parameters
→
see
“MODE button functionality” page 9
), holiday mode is active. Other-
wise the contact or sensor status configured in the “not occupied holiday” or “energy saving” mode has priority over manual
setting.
When timer extension mode is activated manually, it takes priority over energy saving, holiday (see
“15. Timer extension
mode” page 27
) and time zone modes (
TH-xxCSx1
models).