36
6
Access case interior
When working inside the unit, avoid contact with the battery, other
exposed components, and any item protected by the unit's interior plastic
cover. Avoid dropping or spilling anything into the case.
•
Using a torx screwdriver with a T25 bit, unscrew and remove the four
fasteners that secure the case lid to the case base. Set aside the
fasteners for later reinstallation.
•
The unit is hinged on the left; open the case lid from right to left.
•
Bring in the customer-supplied Ethernet cable, power lines, or both
through the customer-installed conduit-hub. If both an Ethernet cable
and fixed DC power will be used, it is recommended that one conduit
be used for the Ethernet cable and the other for the power lines,
following AHJ requirements.
•
Use the diagram below, left, to locate the optional connection ports
to be used: the terminal block, Ethernet cable port, and guides.
Protective cover
Guides (4x)
Terminal block
RJ45 port
7
Connect power
Choose
only
one option below (a or b) to select an external power input
for the RGX and follow that set of instructions.
WARNING:
The RGX offers these power-input options: 12 V Charger
Port, IS Power Port, and 9
–
30 VDC Terminal Block. When connecting
external power, select only a single power-input type;
connecting multiple
power inputs is
not supported
.
a Power supply accessory (ISERTPS or ERTPS)
IMPORTANT
:
The
warning
above also applies to this option.
If the RGX will draw operational power from a compatible power supply
accessory (ISERTPS or ERTPS), connect the power supply's IS cable to
the unit’s IS Cable Adapter.
Ensure that the ISERTPS or ERTPS is installed, connected, and used in
accordance with the instructions provided in its product manual.
Terminal block (detail)
GND
b Fixed DC power
IMPORTANT
:
The
warning
above also applies to this option.
To complete the fixed DC power connections, count the terminal-block
ports from left to right, locating the fifth and sixth ports.
•
Connect the ground line to Port 5, labeled "GND".
•
Connect the compatible fixed DC power line to Port 6, labeled "PWR
IN 9V-30V ". This line supplies input voltage in the specified range
with a maximum current of 5.0A.
PWR IN