Power On and Shutdown
Locate the power button on the case lid.
Power on
Press the power button for approximately 5 seconds until the power-button light turns on.
•
If the unit is fully operational, the power-button light will be solid (not blinking) green.
•
For information about other light patterns and colors, see
Table 3.6 Power-button light indicators
Shutdown
Press the power button for approximately 7 seconds.
•
When the power-button light starts to blink, release the button.
•
To indicate unit shutdown is in progress, the light will blink red and green.
•
To indicate the unit is fully shutdown, the light will turn off.
Note
: An RGX Gateway set for
“always
-
on”
operation
cannot be manually shut down
and will ignore manual
shutdown attempts until this is deactivated via iNet.
Configuration
RGX configuration requires the use of one or two "apps", the RGX Configuration Interface (Interface) and
iNet software. Generally, as outlined below, the Interface is used to configure RGX-to-iNet communication
settings; iNet software is used for all other RGX settings (see below). After initial configuration, use each
app as needed to edit the settings it supports.
Table 3.2 Configuration applications
App
RGX Configuration
Interface
iNet software
Supported settings
Always-on functionality
No
Yes
iAssign Beacon (access level and range)
No
Yes
LENS repeater mode
No
Yes
LENS Wireless (group and encryption key)
No
Yes
RGX-iNet communication (cellular, wi-fi, and
Ethernet)
Yes
No
Site name (also serves as Beacon site name)
Yes
Yes
Other (GPS, data upload intervals, communication
priority, etc.)
No
Yes
Accessing and using the RGX Configuration Interface app
If the unit's communication setting will be cellular
only
, then you do
not
need to access or complete any
work in the RGX Configuration Interface; skip to
Summary of Contents for RGX Series
Page 22: ......
Page 26: ......
Page 48: ......
Page 58: ...48 Figure A 1 B External electrical connections in a nonhazardous location To Figure A 1 A ...
Page 59: ...49 Figure A 1 C Internal electrical connections ...
Page 60: ......