15
You will need to make decisions about the RGX GPS and noncritical data settings.
•
Determine if the unit will operate with its GPS on or off. When on,
the unit can acquire its GPS
coordinates and send this location data to iNet. Importantly, the GPS data are used by iNet Now users
to identify the location of an RGX that has sent data from an in-alarm gas detector. Location data are
also useful for tracking units that will be transported among sites. If the unit's GPS will be on, determine
the interval (1
–
60 minutes) at which the unit will send its location data to iNet.
•
Determine the interval (minutes) at which the unit will send its noncritical data to iNet to support the
live-monitoring capabilities of iNet Now.
•
When setting intervals, consider the application. For example, while a longer interval for sending GPS
data uses less battery power, a shorter interval may be better suited if the RGX will be frequently
moved among sites.
Connections are generally maintained, when no interference is present, by keeping the equipment items
within their range guidelines (see Table 2.2 below). Provided the required LENS Wireless connections are
maintained, the live-monitoring of equipment items accommodates worker and equipment
movement.
Table 2.2 Range guidelines to maintain LENS Wireless connections
Line-of-sight distance, maximum
LENS Power Mode Setting
Equipment items
World setting
CE RED
b
setting
RGX to equipment items
RGX to RGX
a
(World)
—
300 m (328 yd)
185 m (202 yd)
RGX to RGX
a
(CE RED)
—
185 m (202 yd)
185 m (202 yd)
RGX to Ventis Pro
100 m (109 yd)
—
—
RGX to Radius BZ1
—
300 m (328 yd)
185 m (202 yd)
c
Instrument to instrument
Ventis Pro to Ventis Pro
100 m (109 yd)
b
—
—
Ventis Pro to Radius BZ1
100 m (109 yd)
b
—
—
Radius BZ1 to Radius BZ1
300 m (328 yd)
185 m (202 yd)
c
a
Also applies to RGX units operating in LENS repeater mode: RGX to LENS repeater, LENS repeater to LENS repeater, and LENS
repeater to RGX.
b
in the
front matter
of this manual.
c
Applies when the equipment items face each other.
To learn more about the Ventis Pro® or the Radius® BZ1, consult its product manual.
Summary of Contents for RGX Series
Page 22: ......
Page 26: ......
Page 48: ......
Page 58: ...48 Figure A 1 B External electrical connections in a nonhazardous location To Figure A 1 A ...
Page 59: ...49 Figure A 1 C Internal electrical connections ...
Page 60: ......