Maintenance Summary - Care activities
It is recommended to document the maintenance activities carried out by using the appropriate
maintenance log. The maintenance log has the document number DIE245EN - 15.08.2022.
The maintenance interval is highly dependent on the production and environmental conditions of the
machine. The determination of the appropriate interval must be made by the operator.
The maintenance interval should be between once per shift and once a week!
- Check the work area door and window pane
- Check hydraulic system (visual inspection)
- Replace the breathing filter at the filler neck of the hydraulic fluid tank.
- Clean covers of Tur. II. Remove and clean covers.
- Check pneumatic system (visual inspection)
- Check filters on main spindle cooling fan
- Check filter on control cabinet cooling fan
- Check filter on air conditioner cooling fan
- Check fill levels of the fluid tanks
- Clean and lubricate clamping device
- Check electrical lines (visual inspection)
- Visual inspection of all fluid lines and electrical cables
- Clean cooling lubricant outlet on clamping cylinder
- Clean filter screens on chip conveyor
- Check cooling lubricant (visual inspection)
- Check work area light (visual inspection)
- Clean telescopic covers and wipers
- Clean the work area
- Lubricate machine according to lubrication chart
- Lubricate in sync
- Clean the chip conveyor
- Clean labyrinth ring of spindles
Maintenance Summary - Care activities
6
Maintenance Instructions
ABC.2
DIE244EN - 15.08.2022