Hydraulic unit ABC
X
Hydraulic fluid filter
Y
Filter bowl
Replace filters (Z) of the hydraulic fluid filters (X). A different number of
hydraulic filters (X) may be installed, depending on the version. Unscrew filter
bowl (Y), remove contaminated hydraulic fluid (oil sump) and used filter (Z) from
the filter bowl (Y) and dispose of them according to environmental regulations.
6.
Only filters with retained particle sizes described in the fluid
plans must be used.
Example: Filter (Z)
Clean filter bowl (Y) and insert a new filter (Z). Reinstall the filter bowl (Y) and
tighten by hand until it stops. Then back off the filter bowl (Y) 1/8 turn.
Maintenance Summary - 4.000 Operating hours
91
Maintenance Instructions
ABC.2