67
Note that the MVN-XC440 will use this program number only if it not already in use,
otherwise it will use the closest available number. For example, if there is a Program 1
already established in the output, and a second program is added with a requested
program number of 1, the actual program number will be 2. The actual program numbers
can be found in The Current Connections Table.
Establishing the Connection
Once the connection is configured, click on
Apply
to establish it. If the source and destination
have been completely specified, the connection is established and added to the
Current
Connections
Table. If any information is missing, the MVN-XC440 will take no action.
Clicking on the
Cancel
button will clear all selections.
The Current Connections Table
As connections are established (either in the Connections tab, or as part of the output port
configuration), they are added to the Current Connections table. Regardless of how they got
added, the connections can be edited or deleted using the functions in this table. A sample of this
table is depicted below.
The following columns are available in this table:
Source Port, Source Name:
these columns have the current source for the connection.
Source Port indicates the type of port, and Source Name indicates the configured name
for the stream. The Source Name column will change to indicate address/port (for IP
Inputs) if
Stream Display
is set to
Stream Addresses
.
Source Program:
this column has the actual source program number. It will have a
value of 0 (zero) if the program is not present.
Status:
this column indicates whether or not the routed program is present in the input. It
will indicate
OK
if the routed program exists or
No Program
if the routed program is not
present in the input.
Destination Port, Destination Name:
this column contains the destination for the
connection, in the same fashion as the Source Port and the Source Name. The
Destination Name column will change to indicate address/port if
Stream Display
is set to
Stream Addresses
.
Destination Program:
this column contains the actual destination program number for
the connection. It will have a value of 0 (zero) if the program is not present.
Remove:
check this box if you want to delete specific connections. The connections will
be deleted if you click on the
Apply
button. Clicking on
Cancel
un-checks all rows.