Loudness Alarm Setup Menu
Menu Selections
Table 5-3
Loudness Alarms Setup Menu
Selection Option
Selection Option
Selection Option
High Level Above
Enable
Level
0 to 10 LU
(The default selection
depends on the Loudness
Mode selection; see Note
below)
Duration
0 to 60 seconds (2
seconds*)
Low Level Below
Enable
Level
0 to 10 LU
(The default selection
depends on the Loudness
Mode selection; see Note
below)
Duration
0 to 60 seconds (2
seconds*)
Menu Selection Descriptions
High Level Above
:
The High Level Above target alarm occurs when the integrated
loudness level is higher than the target value plus the range above the desired loudness
level for a period in excess of the duration setting.
Low Level Below
: The Low Level Below target alarm occurs when the integrated
loudness level is lower than target value plus the range below the desired loudness level
for a period in excess of the duration setting.
These values are mode-dependent (ATSC A/85, EBU R 128, ARIB TR-B32, or Custom). When
you are in a specific mode you can only adjust the parameters associated with that
particular mode. When you change a loudness mode’s parameter, the High Level Above and
the Low Level Below target alarm parameters change also.
Summary of Contents for Videotek LLM-1770
Page 13: ...LLM 1770 Installation and Operation Manual 7 Figure P 3 WEEE Compliance Symbol...
Page 14: ...About This Manual 8...
Page 62: ...Chapter 4 Setup Menu Functions 56...
Page 68: ...Chapter 5 Alarm Descriptions 62...
Page 76: ...Chapter 6 External Control 70...
Page 84: ...Chapter 8 Specifications 78...
Page 102: ...Appendix C Glossary 96...
Page 122: ...Index 116...