Chapter 5
Alarm Descriptions
58
Meter Based Alarms Setup Menu
Menu Selections
Table 5-2
Meter Based Alarms Setup Menu
Selection
Selection Option
Selection Option
Peak Audio
Enable Meter 1 •• 8
Level
-30 to 0 dBFS
(The default selection
depends on the Loudness
Mode selection)
Duration
0 seconds to 60 seconds (2
seconds*)
Loss of Sound
Enable Meter 1 •• 8
Level
-60* to 0 dBFS
Duration
0 seconds to 60 seconds (2
seconds*)
Digital Clip
Enable Meter 1 •• 8
Sensitivity
1 to 100 CES (50 CES*)
Duration
0 seconds to 60 seconds (2
seconds*)
Digital Mute
Enable Meter 1 •• 8
Sensitivity
1 to 100 CES (50 CES*)
Duration
0 seconds to 60 seconds (2
seconds*)
Default values for meter-based alarms are mode dependent (i.e., ATSC A/85, EBU R 128,
ARIB TR-B32, or custom). Parameters are retained separately for each mode.
Menu Selection Descriptions
Peak Audio
: The Peak Audio alarm occurs when the peak audio level exceeds the
adjustable limit for a period in excess of the duration setting. The level limit can be set
from -30 dBFS to 0 dBFS, in 1 dB increments. The peak audio duration can be set from
0 to 60 seconds.
Loss of Sound
: The Loss of Sound alarm occurs when the peak amplitude falls below
an adjustable limit for a period in excess of the duration setting. The audio range is -60
dBFS to 0 dBFS, in 1 dB increments. The Loss of Sound duration can be set from 0 to 60
seconds.
Digital Clip
: The Clip alarm occurs when the audio is at a maximum level for a period
in excess of the duration setting. For the LLM-1770, the accuracy of the audio clip
alarm is 0.1 dB.
Digital Mute
: The Mute alarm occurs when the audio sample is “0” for a period in
excess of the duration settings.
Summary of Contents for Videotek LLM-1770
Page 13: ...LLM 1770 Installation and Operation Manual 7 Figure P 3 WEEE Compliance Symbol...
Page 14: ...About This Manual 8...
Page 62: ...Chapter 4 Setup Menu Functions 56...
Page 68: ...Chapter 5 Alarm Descriptions 62...
Page 76: ...Chapter 6 External Control 70...
Page 84: ...Chapter 8 Specifications 78...
Page 102: ...Appendix C Glossary 96...
Page 122: ...Index 116...