Chapter 2
Installation
18
Initial Configuration
Before you can connect to an X50 using a web browser, you must configure the IP address
of the frame. Follow these steps:
1
Connect one end of a crossover or passthrough cable to the
Ethernet
port on the front of
the X50, and then connect the other end of the cable to a PC with the required software.
The frame automatically detects the cable type and assigns an IP address to the computer
so that they are on the same subnet. You can also set the IP address on the frame itself if
the frame has a front control panel.
2
Launch a browser and type anything in the address bar.
The X50 control interface appears.
3
Select
Configuration
and ensure that the Frame Controller is selected in the tree view at
the left of the screen.
4
On the Frame Control Panel, select
General
.
5
On the
Basic
screen, enter an IP address for the frame.
The IP address should be consistent with your network’s configuration. For more
information, contact your network administrator.
6
Connect the X50 to a hub on your network.
7
Follow the instructions in
Logging In To the X50 Control Interface
.
Logging In To the X50 Control Interface
To open a browser connection to an X50, follow these steps:
1
In your browser, enter the IP address of the X50, and then click
Enter
to connect.
If the X50 is in a failed state (i.e., disconnected), then you will see a “browser cannot display
the page” or “browser could not connect” message.
2
Enter a defined user name and password.
The default user name is Administrator, and by default there is no password (leave the field
blank).
3
Click
Enter
.
The
X50
control interface appears.
The number of PCs connected to the X50 has an impact on receiving data in a timely
fashion. If a large number of users are logged into the frame, response time may become
slower. Up to ten separate PCs can be connected to the X50 at any one time. If additional
users attempt to connect to the X50, they will receive a message:
Server Busy. Please try again later.
When you are not actively using the interface, please log off out of the system.
Note:
The IP address is assigned to the frame, not the controller module. When you change
Controller modules, you should not have to reassign the IP address.