Appendix C
Servicing
118
Changing Jumper Settings
The analog audio input on the X50 can be set to either
600
or
Hi-Z
impedance (see
on page 118). There are eight jumpers for this purpose, located near the rear of
the main board inside the X50. (The default setting is
Hi-Z
.) The diagram on the circuit
board shows how to align the jumpers.
To access the jumpers, follow these steps:
1
Remove the X50 cover, as described on page 106, ensuring
both
power supplies are
disconnected.
2
Set the jumpers as required (
WARNING: You can receive an electric shock from exposed parts of the power
supplies. Ensure that you remove AC power from both power supplies before you
open the cover.
Figure C-20
Analog Audio Input Jumpers J14 to J21