18
VMG-14+ Chassis and Components
Gen2 Release 1.4.0
Basic
Chassis
Populations
Slot assignments determine where to load the system modules, SCMs, fan trays, air filter, and (for AC)
power supply units. The VMG-14+ supports the components and modules listed in
:
Table 3.
VMG-14+ Chassis Modules and Components
Name
Description
System
Capacity
Slot Assignments
Network Control
Processor (NPM and
NPM2)
Either NPM type provides management
functions and ingress/egress for transport
streams.
The NPM2 also provides packet inspection.
Compatibility Notes:
• The NPM is compatible with the TCM
card.
• The NPM2 is compatible with TCM2 or
TCM2+ cards.
• Various models of NPM cards cannot be
mixed. Use only NPM or only NPM2 cards
in your VMG-14+.
See also
“Network Processor Modules” on
• NPM: 2
or
• NPM2: 2
Front,
slots 1 and 2.
System modules
Family of modules that includes AMP, TCM,
TCM2, TCM2+, and VPM.
Compatibility Notes:
• The TCM, AMP, and VPM is compatible
with NPM.
• The TCM2 or TCM2+ is compatible with
NPM2 only.
• Various models of TCM cards cannot be
mixed.Use only TCM, TCM2, or TCM2+ in
your VMG-14+.
See also
• AMP:
2
• Others: up
to
12
Front,
slots 3 through 14.
Shelf Control
Manager (SCM)
Manage power and cooling, and system
inter-connectivity via interaction between
the SCM and Intelligent Management
Controllers (IPMC) over IPMB-0.
Enable system management through
Ethernet.
See also
2
Front, vertically
stacked slots at left
of Slot 1.
SCM2 (top)
SCM1 (bottom)
DC Power Entry
Modules (PEMs)
See also
4
Rear: in power bay
of DC systems.
DC PEM Terminal
Block Cover(s)
4
For attachment to
DC PEM(s)
AC Power Entry
Modules
See also
.
4
Rear: in power bay
of AC systems.
AC Power Supplies
4
Front:, in power bay
of AC systems.