Compliance
Gen2 Release 1.4.0
Compliance
Safety
Table 24.
Regulatory Standards Compliance
Category
Standard
Safety
cTUVus 60950-1:2005 2nd Edition CB Certificate
EMC
FCC - Title 47 CFR Part 15, Subpart B
Canada - ICES-003, Issue 2, April 1995
CE Mark - EN55022 2006 and EN55024:1998 + A1:2001 + A2:2003
EMI
FCC part 15 Class A
Conducted Emissions EN 55022 Class A
Radiated Emissions EN 55022 Class A
Electromagnetic Compatibility EN50082-1:1992-1997 - Generic Immunity
Standard, Part 1: Residential, commercial and light industry.
ESD Immunity EN61000-4-2
Level 3, air at 8 kV, contact at 4 kV, Criteria A
Radiated RF Field Immunity EN6100-4-3
80-1000 MHz, 3 V/m, Criteria A, Modulation: 1 kHz, 80% AM, 1% step size.
Immunity to Electrical Fast Transients EN61000-4-4
Signal Ports: Level 2, 0.5 kV, Criteria A
Power Line: Level 2, 1 kV, Criteria A
Surge Immunity EN61000-4-5
1.0 kV, 1.2/50-8/20uS, Criteria B, Un-balanced Indoor Cables and shielded
cables, Common Mode.
Not applicable to Intra-system cables.
Not applicable to Un-shielded cables that will not operate through CDN.
RF Conducted Immunity EN61000-4-6
Power Lines, level 3,.15 MHz-80 MHz, 3 V emf, Criteria A, Modulation 1 kHz,
80% AM, 1% Step size.
Signal lines, level 3, 150 kHz-80 MHz, 3 V emf, Criteria A, Modulation: 1 kHz,
80% AM, 1% Step size.
Compliant
RoHS
Compliant
Table 25.
Safety Specifications
Parameter
Value
Protected earth test
EN 60950, test current 25 A, resistance <100mOhm