Controller
Section 7: Utility Functions
5760-121 Operations Manual Rev B
Page 65 of 115
Indicates one or more print heads in that task’s daisy chain are not at operating tempera-
ture. Look at the "At Temperature" LED on the back of the individual print heads to identify
which print head is not "at temp."
Indicates the ink supply is
OK
.
Indicates an
Ink Low
condition: the CIDS3000 ink delivery system’s reservoir is out of ink.
Indicates an
Ink Out
condition: one or more print heads in the task’s daisy chain have an
empty ink reservoir. Printing stops.
Indicates the ink waste bottle on the CIDS3000 is less than full, and the ink pump is supply-
ing sufficient ink to the print heads.
Indicates the waste bottle on the CIDS3000 is full and needs to be changed, or the ink
pump has run continuously for more than ten seconds (indicating a possible ink line break)
and has shut down. A look at the waste bottle should determine which fault occurred. Print
head Auto Cleaning System is disabled in either case.
Indicates the task’s interface board has been successfully programmed.
Indicates the task’s interface board did not program properly and that it is not functioning.
Summary of Contents for IJ300
Page 2: ......
Page 4: ......
Page 6: ......
Page 12: ...Controller Section 1 Introduction Page 2 of 115 5760 121 Operations Manual Rev B...
Page 14: ...Controller Section 2 Safety Page 4 of 115 5760 121 Operations Manual Rev B...
Page 18: ...Controller Section 3 Typical System Components Page 8 of 115 5760 121 Operations Manual Rev B...
Page 32: ...Controller Section 4 Getting Started Page 22 of 115 5760 121 Operations Manual Rev B...
Page 72: ...Controller Section 6 Message Functions Page 62 of 115 5760 121 Operations Manual Rev B...
Page 82: ...Controller Section 7 Utility Functions Page 72 of 115 5760 121 Operations Manual Rev B...
Page 94: ...Controller Appendix B Theory of Operation Page 84 of 115 5760 121 Operations Manual Rev B...
Page 96: ...Controller Appendix C Parts and Supplies Page 86 of 115 5760 121 Operations Manual Rev B...
Page 100: ...Controller Appendix D Performance Parameters Page 90 of 115 5760 121 Operations Manual Rev B...