Controller
Section 5: Setup Functions
Page 30 of 115
5760-121 Operations Manual Rev B
Serial Port Setup
To set the COM1 and COM2 serial port device type and baud rate:
1. On the Home screen, touch the
Control Panels
button to open the Control Panels
Menu.
2. Touch the
System Setup
button on the Control Panels Menu to open the System
Setup screen.
3. Touch the
Serial Ports
tab on the System Setup screen to display the Serial Ports
page.
4. Touch the COM1 or COM2
Function
box to open a list box and select a device for the
related port.
5. Touch the COM1 or COM2
Bits per second
box to open a list box and select a baud
rate for the related port.
NOTE
: The following settings are fixed on the IJ3000 and cannot be changed. Any device
connected to an IJ3000 serial port must be configured to match these settings:
Data Bits: 8
Stop Bits: 1
Parity: None
Flow Control: None
Summary of Contents for IJ300
Page 2: ......
Page 4: ......
Page 6: ......
Page 12: ...Controller Section 1 Introduction Page 2 of 115 5760 121 Operations Manual Rev B...
Page 14: ...Controller Section 2 Safety Page 4 of 115 5760 121 Operations Manual Rev B...
Page 18: ...Controller Section 3 Typical System Components Page 8 of 115 5760 121 Operations Manual Rev B...
Page 32: ...Controller Section 4 Getting Started Page 22 of 115 5760 121 Operations Manual Rev B...
Page 72: ...Controller Section 6 Message Functions Page 62 of 115 5760 121 Operations Manual Rev B...
Page 82: ...Controller Section 7 Utility Functions Page 72 of 115 5760 121 Operations Manual Rev B...
Page 94: ...Controller Appendix B Theory of Operation Page 84 of 115 5760 121 Operations Manual Rev B...
Page 96: ...Controller Appendix C Parts and Supplies Page 86 of 115 5760 121 Operations Manual Rev B...
Page 100: ...Controller Appendix D Performance Parameters Page 90 of 115 5760 121 Operations Manual Rev B...