Controller
Section 7: Utility Functions
5760-121 Operations Manual Rev B
Page 69 of 115
System Test
Touch Screen Calibration is completed at the factory. This calibration can be performed any
time there are problems with the touch screen. From the
Home Screen
, select
Show
Menu, Control Panels
, then
Utilities
. Choose
Calibrate Touch
Screen
and touch
Do
Function
.
If the touch screen is so far out of calibration that it is inoperable, you will have to call up the
calibration utility using the keyboard. From the
Home Screen
, press the space bar to dis-
play the Home Screen menu (the space bar alternately hides and displays the menu), then
press the "
T
" key.
Follow the instructions on the display.
If calibration is successful, the
Success
screen appears.
Press
OK
to confirm.
If calibration is not successful, the
Calibration Failure
screen appears. Touch
Yes
, and
attempt calibration again. If it continues to fail after several tries, call the Diagraph Support
Line.
Summary of Contents for IJ300
Page 2: ......
Page 4: ......
Page 6: ......
Page 12: ...Controller Section 1 Introduction Page 2 of 115 5760 121 Operations Manual Rev B...
Page 14: ...Controller Section 2 Safety Page 4 of 115 5760 121 Operations Manual Rev B...
Page 18: ...Controller Section 3 Typical System Components Page 8 of 115 5760 121 Operations Manual Rev B...
Page 32: ...Controller Section 4 Getting Started Page 22 of 115 5760 121 Operations Manual Rev B...
Page 72: ...Controller Section 6 Message Functions Page 62 of 115 5760 121 Operations Manual Rev B...
Page 82: ...Controller Section 7 Utility Functions Page 72 of 115 5760 121 Operations Manual Rev B...
Page 94: ...Controller Appendix B Theory of Operation Page 84 of 115 5760 121 Operations Manual Rev B...
Page 96: ...Controller Appendix C Parts and Supplies Page 86 of 115 5760 121 Operations Manual Rev B...
Page 100: ...Controller Appendix D Performance Parameters Page 90 of 115 5760 121 Operations Manual Rev B...