Controller
Section 5: Setup Functions
5760-121 Operations Manual Rev B
Page 27 of 115
Encoder Setup
Touch the
Encoder
tab at the bottom of the
System Setup
screen to access encoder
options.
Touch either the External encoder, at left, or the Internal timer, at right. The choice will be
indicated by a gray box on the screen.
The External encoder is used if the line speed varies or has frequent starts and stops. Res-
olution cannot be changed; it is fixed at 300 pulses per inch (ppi) for Impulse Jet, and 100
ppi for Integrated Valve.
The Internal timer is used if the line speed is constant, with a minimum of starts and stops.
If choosing the internal timer, it is necessary to set the conveyor line speed that will be
used. (See
Appendix D: Performance Parameters
for maximum line speeds).
NOTE:
When configuring Task 2, a different encoder setup screen is displayed with the
option of using the Task 1 encoder and/or photosensor. (For more on hardware configura-
tion, see the system operation manual.)
Touch
OK
to return to the
Home Screen
.
Summary of Contents for IJ300
Page 2: ......
Page 4: ......
Page 6: ......
Page 12: ...Controller Section 1 Introduction Page 2 of 115 5760 121 Operations Manual Rev B...
Page 14: ...Controller Section 2 Safety Page 4 of 115 5760 121 Operations Manual Rev B...
Page 18: ...Controller Section 3 Typical System Components Page 8 of 115 5760 121 Operations Manual Rev B...
Page 32: ...Controller Section 4 Getting Started Page 22 of 115 5760 121 Operations Manual Rev B...
Page 72: ...Controller Section 6 Message Functions Page 62 of 115 5760 121 Operations Manual Rev B...
Page 82: ...Controller Section 7 Utility Functions Page 72 of 115 5760 121 Operations Manual Rev B...
Page 94: ...Controller Appendix B Theory of Operation Page 84 of 115 5760 121 Operations Manual Rev B...
Page 96: ...Controller Appendix C Parts and Supplies Page 86 of 115 5760 121 Operations Manual Rev B...
Page 100: ...Controller Appendix D Performance Parameters Page 90 of 115 5760 121 Operations Manual Rev B...