5 - 24
5. OPERATION
9.
When “DPC DATA: OK” or “DPC DATA: RETRY” is displayed, select the following item and press the MENU switch.
Turning the MENU switch switches over the display as shown below. Press the MENU switch when the desired item is
displayed.
→OK→GAIN 18dB→GAIN 12dB→ACCUM ON→END-→END+→START-→START+→EFF CHK→RETRY→CANCEL
• Pressing the MENU switch at “OK” saves the defect correction data.
• Pressing the MENU switch at “GAIN 18dB” allows the operator to check the pixel correction at 18dB.
• Pressing the MENU switch at “GAIN 12dB” allows the operator to check the pixel correction at 12dB.
• Pressing the MENU switch at “ACCUM ON” allows the operator to check the pixel correction at accumulation 1/10s.
• Pressing the MENU switch at “END-, END+, START-, START+” allows the operator to displace the pixel correction
position by one pixel.
It is used for the additional pixel correction and the displacement of the pixel correction position.
Correction range
defect
Appropriate
correction range
START
-
+
-
+
END
As described in the figure, it can be corrected within the appropriate correction range to the defect by START+ and END-.
• Switching to “CANCEL” and pressing the MENU switch, defect correction data becomes invalid and cannot be saved.
However, the defect correction data already saved is not deleted.
• Pressing the MENU switch at “RETRY” retries defect correction.
• Pressing the MENU switch at “EFF CHK” allows the operator to check the defect is properly corrected.
10.
Press the MENU switch to move to the sub menu.
[Verifying correction state]
1.
Turn the MENU switch to select “DPC EFFECT CHK” and press it. The blinking cursor moves to the mode.
2.
Turn the MENU switch to select the desired value (“OK” or “CANCEL”) and press it.
• Selecting “OK” displays blinking “PUSH SET
→
START” on the lower side of the screen.
• Selecting “CANCEL” cancels the verification of the defect correction state.
3.
When “OK” is selected, press the MENU switch again. “DPC ON” and “DPC OFF” are displayed alternately for a few
seconds.
• DPC ON: Displays the state after the defect correction on the screen.
• DPC OFF: Displays the state before the defect correction on the screen.