5. OPERATION
5 - 21
■
AUTO SETUP
AUTO SETUP MODE
QUIT
AWB WITH A.IRIS
ON
AWB DETECT AREA
WIDE
AWB MARKER
OFF
AWB REFERENCE
ON
REFERENCE SET
ABB
AWB CC CONTROL
ON
BLACK BALANCE
ABS+APS
(OFF, ON)
(WIDE, SPOT)
(OFF, ON)
(OFF, ON)
(ABB, AWB)
(OFF, ON)
(ABS, APS, ABS+APS)
When the MENU select switch is pressed on the item to be set, the value on the right
blinks.
Keeping this state, turn the MENU select switch to select the desired value and press it.
[AWB WITH A.IRIS]
• ON: Forcibly controls the IRIS to perform AWB at 100% picture level.
• OFF: Performs AWB with the current IRIS value.
[AWB DETECT AREA]
• WIDE: Performs AWB using about 80% of the screen as the measurement area.
• SPOT: Performs AWB using about 10% (center) of the screen as the measurement area.
[AWB MARKER]
• ON: Displays a marker for the area measured for AWB.
• OFF: Does not display a marker for the measurement area.
[AWB REFERENCE]]
• ON: Performs AWB based on the value set for “REFERENCE SET.”
• OFF: Performs AWB based on the picture level of G ch.
[REFERENCE SET]
Set the convergence values when AWB and ABB are performed.
When AWB and ABB are selected, “PUSH SET
→
START” blinks on the lower side of the menu screen. When the
MENU switch is pressed again at this time, AWB and ABB are performed. When you do not perform AWB and ABB, rotate
the MENU switch and move to another item.
• AWB
• ABB
1.
Set “AWB REFERENCE” to “ON.”
1.
Set the PED value.
2.
Set the GAIN value for each channel.
2.
Perform “REFERENCE SET.”
3.
Perform “REFERENCE SET.”
3.
Perform “ABB” to converge to the set value.
4.
Perform “AWB” to converge to the set value.