![Ihse Draco tera 480 Series User Manual Download Page 126](http://html.mh-extra.com/html/ihse/draco-tera-480-series/draco-tera-480-series_user-manual_623696126.webp)
Draco tera
126
2020-02-26
OSD
➔
Select
Configuration > EXT Units
in the main menu.
Menu Configuration
– EXT Units
1. Insert the SFP modules into the matrix and connect the extenders
according to the required application.
One extender will be created for each SFP module in the
EXT Units
list. The appropriate names always start with "UNI".
2. In order to configure a CON Unit, select one of the extenders in the
EXT Units
list that are physically connected to a USB CON Unit.
3. Edit the extender by setting the
USB-CON
(
standalone
) option in the
Input Signals
field to
Y
for
C#1
. Set additionally the
Universal-CPU
option in the
Output Signals
field to
N
for
C#1
.
4. In order to configure a CPU Unit, select one of the extenders in the
Ext Units
list that are physically connected to a USB CPU Unit.
5. Edit the extender by setting the
USB-CPU
(
standalone
) option in the
Output Signals
field to
Y
for
C#1
. Set additionally the
Universal-
CPU
option in the
Input Signals
field to
N
for
C#1
.