5
UK
2 Safety instructions
•
Please read this document prior to set-up of the unit� Ensure that the product is
suitable for your application without any restrictions�
•
If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property can occur�
•
Ensure before mounting the components into or removing them from the
compressed air system that the installation is at a standstill and no pressure is
applied�
•
Improper or non-intended use may lead to malfunctions of the unit or to un-
wanted effects in your application� That is why installation, electrical connec-
tion, set-up, operation and maintenance of the unit must only be carried out by
qualified personnel authorised by the machine operator�
•
In order to guarantee the correct condition of the device for the operating time
the device must only be used in media to which the wetted parts are sufficiently
resistant (→ Technical data).
•
The responsibility whether the measurement devices are suitable for the
respective application lies with the operator� The manufacturer assumes no
liability for consequences of misuse by the operator� Improper installation and
use of the devices result in a loss of the warranty claims�
3 Functions and features
The unit monitors the standard volume flow of compressed air in industrial use�
It detects the 4 process variables flow velocity, volumetric flow quantity, consumed
quantity, medium temperature�
•
Application: compressed air systems in industrial use�
•
All indications apply for standard volume flow to DIN ISO 2533, i�e� volume flow
at 1013 hPa, 15 °C and 0 % relative air humidity�
The unit can be set to different standard conditions (→ 9.5.8 and → 9.5.9).
•
The general operating conditions of compressed air equipment apply�