If compressed air is fed into the main pipe through parallel pipes, the unit
should be mounted in the main pipe�
•
Installation downstream of the maintenance unit is also possible (if oil is used
for the loads, the units must be mounted upstream of the oiler)�
5.2 Installation conditions
Recommendation:
►
Use a straight inlet pipe with a length of 20 x pipe diameter�
►
In case of disturbances on the inlet side caused by elbows, valves, slides etc�
use an inlet pipe with a length of 50 x pipe diameter�
►
Use a straight outlet pipe with a length of 5 x pipe diameter�
5.3 Installation position
•
Permitted installation positions: pipe length vertical, any position (fig� 1, 2); pipe
length horizontal, unit vertical (fig� 3, 5); unit on side, pipe length left (fig� 4)�
•
Avoid the installation position in fig� 6 (unit on side, pipe length right)� If the flow
rate is low, the specified measurement accuracy cannot be adhered to�