19
UK
9.1.1 Extended menu 1
►
Press [Mode/Enter] until [EF] is
displayed�
►
Press [Set] briefly�
> The first parameter of the submenu is
displayed (here: [HI])�
9.1.2 Extended menu 2
►
Press [Mode/Enter] until [EF] is displayed�
►
Press [Set] briefly�
> [EF2] is displayed�
►
Press [Set] briefly�
> The first parameter of the extended menu [diA] is displayed�
If the extended menu is protected by an access code, [Cod] flashes in the
display�
►
Press and hold [Set] until the valid code no� is displayed�
►
Briefly press [Mode/Enter]�
9.1.3 Locking / unlocking
The unit can be locked electronically to prevent unintentional settings�
►
Make sure that the unit is in the
normal operating mode�
►
Press [Mode/Enter] + [Set] for 10 s�
> [Loc] is displayed�
During operation: [LOC] is briefly displayed if you try to change parameter values�
For unlocking:
►
Press [Mode/Enter] + [Set] for 10 s�
> [uLoc] is displayed�
Factory setting: not locked�