IO-Link Master with EtherNet/IP Interface StandardLine 4 Ports IP 65 / IP 66 / IP 67
64
>
Input assembly (Instance 100): I/O data + acyclic data + diagnosis data
34368
Byte
Content
0...1
Port X01...X04: Digital Input - pin 2 / 4 (DI) (
→
Mapping: digital input data (DI)
(
→ S.
2...3
Status information (
→
Mapping: Status information
(
4...45
Acyclic command area: Response channel (
→
Response channel
(
→ S.
46...47
Port X01: PQI (
→
Mapping: PQI
(
48...63
Port X01: Diagnostic, vendor ID, device ID, events (
→
Mapping: IO-Link port information
(
→ S.
64...65
Port X02: PQI (
→
Mapping: PQI
(
66...81
Port X02: Diagnostic, vendor ID, device ID, results (
→
Mapping: IO-Link port information
(
→ S.
82...83
Port X03: PQI (
→
Mapping: PQI
(
84...99
Port X03: Diagnostic, vendor ID, device ID, events (
→
Mapping: IO-Link port information
(
→ S.
100...101
Port X04: PQI (
→
Mapping: PQI
(
102...117
Port X04: Diagnostic, vendor ID, device ID, events (
→
Mapping: IO-Link port information
(
→ S.
118
Port X01: Input data IO-Link (n bytes)
118+n
Port X02: Input data IO-Link (n bytes)
118+2n
Port X03: Input data IO-Link (n bytes)
118+3n
Port X04: Input data IO-Link (n bytes)
Legend:
n = [2,4,8,16,32]; is determined by the parameter [Process_Data_Length] (
→
Configuration Assembly (Instance 199)
(
→ S.