SmartPLC DataLine with EtherCAT slave interface
142
>
Slot 5 ... 66 – Analogue slaves to AS-i Master 1 and AS-i Master 2
42958
Slot
location
Description
Value range
Length
[Word]
5...66
Input and output values of the
analogue slaves connected to an
AS-i Master 1 and AS-i Master 2
Empty module = module is deactivated
0
IN 1 word A or S = 1-word input data, single or A slave
1
IN 1 word B = 1-word input data, B slave
1
IN 2 word A or S = 2-word input data, single or A slave
2
IN 2 word B = 2-word input data, B slave
2
IN 4 word A+B or S = 4-word input data, A and B slaves or single
slave
4
IN/OUT 1 word A or S = 1-word input and output data, single or A
slave
1
IN/OUT 1 word B = 1-word input and output data, B slave
1
IN/OUT 2 word A or S = 2-word input and output data, single or A
slave
2
IN/OUT 2-word B = 2-word input and output data, B slave
2
IN/OUT 4-word A+B or S = 4-word input and output data, A and B
slave or single slave
4
OUT 1-word A or S = 1-word output data, single or A slave
1
OUT 1-word B = 1-word output data, B slave
1
OUT 2-word A or S = 2-word output data, single or A slave
2
OUT 2-word B = 2-word output data, B slave
2
OUT 4-word A+B or S = 4-word output data, A and B slave or single
slave
4