Slave status: colour code + symbols
41652
Single slave
A/B slave
Colour
Meaning
grey
No slave found:
slave address is neither in the LPS nor in the LDS
green
Slave is activated ( in LAS)
red
Configuration error type 1:
slave is projected (in LPS) but was not found (in LDS)
yellow
Slave signals a peripheral fault
pink
Several slaves have the same address (double address error)
grey red
Configuration error type 2:
the found slave (in LDS) is not projected (in LPS)
the found slave has another profile than projected
>
Meaning of the colour combinations (example: configuration error type 2)
41741
Symbol
Colour
Meaning
grey red
grey
Configuration error type 2:
Single slave is projected (in LPS) but was not found (in LDS).
Instead, a new A slave with the same address was installed.
grey
grey red
Configuration error type 2:
Single slave is projected (in LPS) but was not found (in LDS).
Instead, a new B slave with the same address was installed.
grey red
Configuration error type 2:
A or B slave is projected (in LPS) but was not found (in LDS).
Instead, a new single slave with the same address was installed.