Manage configuration data
The sensor can store up to 8 configuration data files (parameter sets). These files can
be managed in the represented dialogue page. The stored configuration data files are
indicated in the list and are clearly marked by the list numbers.
By means of the selector switch
you can select if a change of the
parameter set via the switching inputs is permissible (selection
) or not
(selection
). For the selection external the active configuration data file is
defined by the status of the switching inputs (see annex page 38).
The following possibilities for a configuration data file are available via the buttons:
•
Create
a new configuration data file:
Select a free list place and activate the
button. A dialogue will open
into which you can enter the name of the new configuration data file. Then con-
tinue to the
dialogue page (page 27).
•
Activate
an existing configuration data file:
With this button you determine the selected configuration data file as active set-
ting. After you have switched on the sensor the evaluation is carried out auto-
matically using the settings from the activated configuration data file.
Set image quality
Create new
internal
external
Program Selection
25
ENGLISH
file location no.
(list of configuration
data files)
activated file
location
information
about the port
information about
the contour sensor
name of activated
data file