www.ies-synergy.com
User Manual
DUM016055-EN
10
Technical specification
Internal AC input protection
Inrush current limitation per phase
I
INRUSH LIMIT
< 3 x I
AC
Max
Rated Current Fuse (per module)
I
BREAK
Rating
80A
typ
Breaking capacity of fuses
I
BREAK
Capacity
80 000A
Max
Max earth leakage current
I
LEAKAGE
< 3,5 mA
Max
Emergency button connection
Yes
Overvoltage category (IEC60664-1)
III
Insulation protection Class (IEC60664-1)
Class I
DC Output
COMBO 2 output voltage
V
DC
_max
530 V
DC
Max
V
DC
_min
200 V
DC
Min
CHAdeMO output voltage
V
DC
_max
500 V
DC
Max
V
DC
_min
150 V
DC
Min
Output current
I
DC
_max
65A
(1)(2)
Max
I
DC
_min
1,5A
Min
Max Output Power
P
OUT
24kW
Max
Output connector (charging station side)
Permanent mounting
Car Plug connector
Plug #1
(5)
COMBO 2
(5)
Plug #2
(5)
CHAdeMO
(5)
Output cable length
Meters
3,5 (5,2 in option) -10/+0%
AC output (for WBG3X_TRI 3PN only)
AC Output voltage
V
AC
_nom
400 V
AC
± 10%
AC Output current
I
AC
_max
32 A
Max
Max Output Power
P
OUT
22 kVA
Max
Car Plug socket
Plug #3
AC type 2 S
Type of connection
Case “B” connection (mode3)
Detachable cable
Internal DC output protection
Hardware and software short circuit protection
Yes
Software and Hardware over voltage protection
adjustable
+10% max
Over temperature protection
-
70
°C
Reverse polarity protection
Yes
DC output Contactor
Yes (2 poles)
Rated Current Fuse (output)
I
FUSE
125
A
Galvanic isolation
V
input / output
4800 (G3)
5200 (G3X)
V
DC
Max time for DC line discharge < 60V
T
<60V
1
s
Internal AC output protection (WBG3X only)
Inrush current
230A during 100 µs
30A during following second
Short circuit Socket I²t
A²s
75 000
Circuit breaker for AC circuit
50A curve C