www.ies-synergy.com
User Manual
DUM016055-EN
12
General & dimensions
Cooling systems
Heatsink with forced air flow by fans IP55
without air filter
Noise (1m, all direction)
Db(A)
65dbA (1m)
Climatic & Environment constraints
Operating temperature (with derating)
-25°C to +55°C
(3)
Storage temperature
-25°C to +60°C
Relative humidity
RH
10% to 95%
Installation altitude
Alt
2 000m
Max
Norms & standards
Radio Equipment Directive (RED)
2014/53/EU
Efficient use of Radio Spectrum (RED)
ETSI EN 301 511 V12.5.1
ETSI EN 301 908-1 V11.1.1
ETSI EN 301908-2 V11.1.2
ETSI EN 301908-13 V11.1.2
ETSI EN 300 330 v2.1.1
Electric vehicle conductive charging system
Part 1: General requirement
IEC 61851-1
Electric vehicle conductive charging system
Part 22: AC Electric vehicle charging station
IEC 61851-22
Electric vehicle conductive charging system
Part 23: DC Electric vehicle charging station
IEC 61851-23
Electric vehicle conductive charging system
Part 24: Digital communication between a DC charging
station and an EV for control of DC charging
IEC 61851-24
Electromagnetic compatibility (EMC)
IEC 61851-21-2
(for G3 only)
EN 61000-3-11
(for G3X only)
EN 61000-3-12
(for G3X only)
EN 61000-6-2
(for G3X only)
EN 61000-6-4/A1
(for G3X only)
EN 301489 v2.2.0
(for G3X only)
EN 301489-17 V3.2.0:2017
(for G3X only)
Insulation Monitor Device (IMD)
IEC 61557-1
IEC 61557-8
RoHS
2015/863/EU
(for G3 only)
2011/65/EU
(for G3X only)
Declaration of conformity CE
(4)
Yes
EV Ready
(for G3X only)
Compliant
(1)
Max output current will be adapted versus maximum carrying current of the vehicle plug.
(2)
Output current can be even reduced with the power derating versus temperature.
(3)
Potential derating above 35°C.
(4)
CE marking affixed on the product attest the conformity of the product with applicable requirements of relevent Community har-
monization legislation.
(5)
On Wallbox G3, you only have one Combo or CHAdeMO connector.