www.ies-synergy.com
User Manual
DUM016055-EN
11
Embedded Insulation device
Response time (tan)
< 3sec. for asymmetrical fault
< 62sec. for symmetrical fault
Self test time
At power on and every 60s during charge
Internal resistance Ri of the measuring circuit
1.5Mohms permanent
750Kohms continuous measurement
300Kohms during simultaneous switching measurement
Measurement method
Continuous and switching measurement resistor method
Measuring current Im
< 1,4mA at RF=0
Measurement range (Ran)
20Kohms…300Kohms
Relative uncertainty
±15%
Line L+/L- Voltage (Un)
DC 150V…530V
System leakage capacity Ce
≤ 1µF : response value (Ran) and time (tan) are not guar
-
anteed for capacity above 1µF
Parallelization
I
Warning:
Do not connect the insulation monitor de-
vice (IMD) in parallel !!
Response value (Ran) and time (tan) are not guaranteed.
Radio Frequency characteristics
The equipment module is designed to provide customers with global network coverage on the connec-
tivity of UMTS/HSPA+, and it is also fully backward compatible with the existing EDGE and GSM/GPRS
networks.
Frequency band (MHz)
Output power (dBm)
Tx
Rx
Min
Max
GSM850/EGSM900 (GMSK)
880-915
925-960
5 ±5dB
33 ±2dB
GSM850/EGSM900 (8-PSK)
880-915
925-960
0 ±5dB
27 ±3dB
DCS1800/PCS1900 (GMSK)
1710-1785
1805-1880
0 ±5dB
30 ±2dB
DCS1800/PCS1900 (8-PSK)
1710-1785
1805-1880
0 ±5dB
26 ±3dB
WCDMA
B1/B2/B4-B6/B8/B19 B1/B2/B4-B6/B8/B19
<-49
24 +1/-3dB
LTE-FDD
B1-B5/B7/B8/B12/
B13/B18-B20/B25/
B26/B28
B1-B5/B7/B8/B12/
B13/B18-B20/B25/
B26/B28
<-39
23 ±2dB
LTE-TDD
B38-B41
B38-B41
<-39
23 ±2dB
RFID reader characteristics
To start a charge, users must swipe a contactless RFID card across the card reader.
Frequency bands
13.56 Mhz
Output power
-5dBuA/m@3m
General & dimensions
External dimensions (mm)
H x W x D
860 x 507 x 250 mm (G3)
1225 x 507 x 250 mm (G3X)
Weight (without cable, or bracket)
kg
66kg (G3)
93kg (G3X)
Max
Type of installation
Wall / Pedestal mounting
Fixation points
8 screws
Protection type (EN60529)
IP55