The information contained in this document is the property of Automatic Systems and is confidential. The recipient shall refrain from using it for any purpose other than the use of the products or the execution of the project to which
it refers, and from communicating it to third parties without Au
tomatic Systems’ prior written agreement. Document subject to change without notice.
BL5x-MT-EN-13
page
15/56
Parameter
Values
Description
Download Chg Lv2
Downloading a version of the control board program that differs
from the one previously installed.
As the difference is of level 2 (modification of the version or the
evolution), all of the parameters are returned to their default
values.
WARNING
: it is then necessary to set the parameters to the
actual configuration of the equipment and to save them in
MEM1.
Note
: it would be wise to keep the parameters values before
changing the program version: Communication parameter
Extract Param (Technician level access).
Download Chg Lv3
Downloading a version of the control board program that differs
from the one previously installed.
As the difference is of level 3 (modification of the type), all of the
parameters are returned to their default values and the counters
are reset to 0.
WARNING
: it is then necessary to set the parameters to the
actual configuration of the equipment and to save them in
MEM1.
Note
: it would be wise to keep the parameters values before
changing the program version: Communication parameter
Extract Param (Technician level access).
Reset Counters
Counters reset to zero following the download of a different
program version of level 3 (see
Download Chg Lv3
).
Curve 229Std
Change in the type of barrier: selection of curve 229 standard
(
Barrier Type
parameter under the
QUICK START
menu).
Curve 229Highway
Change in the type of barrier: selection of curve 229 highway
(
Barrier Type
parameter under the
QUICK START
menu).
Curve 1x-2x-3x-5x
Change in the type of barrier: selection of curve for BL16, BL32,
BL33, BL52, BL53 (
Barrier Type
parameter under the
QUICK
START
menu).
Curve BLG77
Change in the type of barrier: Selection of curve BLG77 (
Barrier
Type
parameter under the
QUICK START
menu).
Curve Special
Change in the type of barrier: selection of the
Special
curve
(
OPTIONS
menu) for operation according to the
OP
REGULATION
and
CL REGULATION
menus.
Curve BL223
Change in the type of barrier: Selection of curve BL223 (
Barrier
Type
parameter under the
QUICK START
menu).
Curve BL40 AVR
Change in the type of barrier: Selection of curve BL40 AVR
(
Barrier Type
parameter under the
QUICK START
menu).
Curve BL40 SR
Change in the type of barrier: Selection of curve BL40SR
(
Barrier Type
parameter under the
QUICK START
menu).
Curve BL41 AVR
Change in the type of barrier: Selection of curve BL41AVR
(
Barrier Type
parameter under the
QUICK START
menu).
Curve BL41 SR
Change in the type of barrier: Selection of curve BL41SR
(
Barrier Type
parameter under the
QUICK START
menu).
Curve BL43 AVR
Change in the type of barrier: Selection of curve BL43AVR
(
Barrier Type
parameter under the
QUICK START
menu).
Curve BL43 SR
Change in the type of barrier: Selection of curve BL43SR
(
Barrier Type
parameter under the
QUICK START
menu).
Curve BL44 AVR
Change in the type of barrier: Selection of curve BL44AVR
(
Barrier Type
parameter under the
QUICK START
menu).
Curve BL44 SR
Change in the type of barrier: Selection of curve BL44SR
(
Barrier Type
parameter under the
QUICK START
menu).