The information contained in this document is the property of Automatic Systems and is confidential. The recipient shall refrain from using it for any purpose other than the use of the products or the
execution of the project to which it refers, and from communicating it to third parties without Au
tomatic Systems’ prior written agreement. Document subject to change without notice.
BL5x-MT-EN-13
page
11/56
The control board is the
interface between the user and the barrier, which manages all the latter’s actions,
including any possible options.
Note: Hereinafter are presented only the functions accessible in Simplified mode and sufficient for daily
use of the equipment.
For a detailed description of all the functions, their parameter setting, etc, please refer to the manual
dedicated to the board (available on request)..
Navigation in the menus of the display screen is based on a pull-down menu architecture on 3 levels:
MENUS
↔ PARAMETERS
↔ VALUES.
Moving from one level to another is achieved via the ◄ ► keys and navigation inside those levels by means of
the ▲ ▼ keys (press for a few seconds to go from the at-rest screen to another menu).
Note
: the second column in the tables below provides the parameter default values as they are entered during
manufacturing of the control board.
Nevertheless, as each equipment has been specifically adjusted in our workshops, the values actually present on
the board may differ slightly.
Menus are displayed in capital
letters on the top line, starting
with the first character of the
LCD.
Hold ▲ or ▼ for a few seconds to
leave the PRDSTD screen and
access the other menus.
Only the first letter of each word in
the parameters is a capital. They are
displayed on the top line starting with
the second character of the LCD (i.e.,
there is a space in front). At the end
of the top line, the parameter unit is
displayed if there is one.
A question mark (?) preceding the
parameter indicates that it is ready to be
modified.
The current value of the parameter appears
on the second line.
A star (*) below a parameter indicates that it
is the default value (set in the factory).
To validate a modification, press the OK
key.
Store the modifications to avoid
them being lost in the event of a
power outage
("QUICK START"
"MEMORY"
"Save")
Menus
Parameter
s
Arm Length
Barrier Type
Arm Type #
? Arm Length
* 3m00
? Arm Length
2m50
? Arm Length
2m00
? Arm Length
6m00
? Arm Length
3m50
? Arm Length
4m00
? Arm Length
4m50
? Arm Length
5m50
? Arm Length
5m00
CANCEL
VALIDATE
or
Values
QUICK START
DATE & TIME
CL REGULATION
PRDSTD - BL_xxx
TIMING
OUTPUT FUNCTION
SENSOR FUNCTION
OK