3. Description
Installation instructions iPump A 3-11
12
Description
Mo
n
ta
g
e H
e
izungsseitig
Heat pump type
iPump A 3-11
Model
400 V
230 V
Unit
Maximum heating supply temperature
°C
62
Regrigerant
-
R410A
Quantity of refrigerant
kg
4.1 (up to 6 m)
CO
2
-Equivalent
t
8.6
Compressor oil
-
EMKARATE RL 32-3MAF
Quantity of compressor oil
l
0.99
Compressor stages
-
1-stage
Air volume outdoor unit (A7°C/W35°C at nominal speed
5
)
m³/h
3.600
Integrated loading pump
Wilo Yonos Para
RS15/7.5_130
Nominal
fl
ow rate heating water (A7°C/W35°C at nominal speed
5
)
m³/h
1.2
Free residual pressure loading pump (A7°C/W35°C at nominal speed
5
)
kPa
40
Pressure loss heating side
kPa
9
Max. pressure heating side (A7°C/W35°C at nominal speed
5
)
kPa
75
Connection dimension
Heating supply / -return
R
1“
Cold- / Warm water connection
R
3/4“
Refrigerant pipe - Hot gas line
Ø mm
16
Refrigerant pipe - Liquid line
Ø mm
12
Maximum length of split-piping between indoor- and outdoor unit
m
20 m /
max. height difference 10 m
4
Electrical data
Electrical power supply compressor
V / Hz
3~400 / 1~230
Electrical power supply heating unit
V / Hz
3~400
Electrical power supply controller
V / Hz
1~230
Maximum operating current of compressor
A
9 / 24
Maximum operating current of ventilator
A
0.5
Maximum power consumption ventilator
W
113
Maximum power consumption heating unit
A
13 / 26
Starting current
A
< 9 / < 24
Performance factor
-
0,97 / 0.99
Fuse of main power supply
A
13 / 25
Fuse of control main supply
A
13
Fuse electrical heater
A
13 / 32
1
If the size of the installation room is lower then the required minimum size, the room must be performed as an engine room according to EN 378
2
12°C cold water temperature / 58°C buffer temperature
3
12°C cold water temperature / 75°C buffer temperature
4
Oil elevation arcs must be installed according to regulation (see page 15)!
5
at 80% pump capacity