Heat pump type
iPump A 3-11
Model
400 V
230 V
Space heating water energy effi ciency class
-
35°C 55°C
Energy effi ciency class water heating
-
Performance data acc. to EN 14511 at nominal speed
Unit
Heat output at A2°C/W35°C
kW
5.92
Power consumption at A2°C/W35°C
kW
1.35
COP at A2°C/W35°C
-
4.37
Cooling capacity at A35°C/W18°C
kW
7.80
Power consumption at A35°C/W18°C
kW
1.81
EER at A35°C/W18°C
-
4,32
Sound emission
Sound power level nominal according to EN 12102 indoor unit
dB(A)
45
Sound power level maximum according to EN 12102 indoor unit
dB(A)
48
Sound power level nominal according to EN 12102 outdoor unit
dB(A)
50
Sound power level maximum according to EN 12102 outdoor unit
dB(A)
53
Sound reduced night operation
dB(A)
49
The sound pressure level can be calculated with the iDM-sound calculation tool
Dimensions indoor unit
Height / Width / Depth
mm
1950 / 600 / 786
Tilted height
mm
2150
Weight
kg
270
Minimum size of installation room
1
m³
9.32
(with standard
fi
lling)
Dimensions outdoor unit
Height / Width / Depth
mm
1180 / 1110 / 745
Weight
kg
113
Hot water tank
Volume of hot water storage tank
l
192
Maximum storage temperature
°C
55
Maximum storage temperature with electrical heating unit
°C
75
Max. single draw of hot water at 46°C tapping temperature - Heat pump
2
l
260
Max. single draw of hot water at 46°C tapping temperature - Electrical heater
3
l
356
Max. single draw of hot water at 40°C tapping temperature - Heat pump
2
l
315
Max. single draw of hot water at 40°C tapping temperature - Electrical heater
3
l
432
Max. operating pressure heating side
bar
3
Max. operating pressure domestic hot water
bar
10
3.7. Technical data